7-9

7.8.2

Routine frequencies

1. Press the [#/SETUP] key, select SCAN FREQ and press the [ENT] key to display the Scan

freq menu.

DISTRESS
2M :

FIXED

4M :

ON

6M : ON
8M :

FIXED

12M : ON
16M : OFF

**

Scan freq setup

*

ROUTINE

F1 :

2M-INTL

F2 : 4M-INTL
F3 : 6M-INTL
F4 : 8M-INTL
F5 : 16M-INTL
F6 : 25M-INTL

2. Select the frequency to process and press the [ENT] key. For example, select 2 MHz.

ROUTINE

F1 : 2M-INTL

F2 : 2M-USR3
F3 : 4M-INTL
F4 : 8M-INTL
F5 : 16M-LCL1
F6 : 25M-LCL2

DISTRESS
2M :

FIXED

4M : ON
6M : ON
8M :

FIXED

12M : ON
16M : OFF

**

Scan freq setup

*

OFF

2 MHZ

4 MHZ
6 MHZ
8 MHZ

$

#

12 MHZ

16 MHZ
22 MHZ
25 MHZ
OTHER

Use

$

to scroll

the menu.

3. Press the [ENT] key, and the display looks something like the one below.

ROUTINE

F1 : 2M-INTL

F2 : 2M-USR3
F3 : 4M-INTL
F4 : 8M-INTL
F5 : 16M-LCL1
F6 : 25M-LCL2

DISTRESS
2M :

FIXED

4M : ON
6M : ON
8M :

FIXED

12M : ON
16M : OFF

**

Scan freq setup

*

INTL

:

T12577.5/R12657.0

LOCAL1 :

T12578.0/R12657.5

LOCAL2 :

T12578.5/R12658.0

$

4. Select frequency desired and press the [ENT] key. INTL are international channels and

LOCAL1/LOCAL2 are local channels. Pressing



selects USER CH, for entry of user

channels (where permitted). Note that selecting OTHER at step 2 displays “**M”.

5. Press the [CANCEL] key twice to return to the DSC standby screen.