Furuno RC-1500-1T User Manual

Page 208

Advertising
background image

5-2

3. Input frequency pair. This can only be done with FURUNO

transceivers.

For other makes of transceiver, set a frequency pair at the trans-
ceiver. Omit steps 1, 2 and 3.

4. Press the [Enter] key.

5. Press function key [F3] again and then the [9] key. The follow-

ing screen appears.

Mode

:

ARQ

FEC

ID :

Manual Calling

Figure 5-3 Manual calling screen

6. Select communication mode.

7. Press the [ ] key and input party's ID number.

8. Press the [Enter] key to connect the communication line. Then,

the line will be connected a short while.

For ARQ mode, follow the next procedure. For FEC mode,
type your message and go to step 13.

9. Press function key [F7] (WRU). The party's answerback code

appears on the screen.

Note:

Step 9 and 10 are needed for ship to ship calling only.

10. Press function key [F8] (HR). You ship's answerback code is

sent to the party.

11. Press the [Enter] key and type your message.

12. If you want to the party's response, press function key [F9]

(Over).

13. Press function key [F10] to disconnect the line.

Advertising