8 scan freq menu, 1 distress frequencies – Furuno RC-1500-1T User Manual

Page 148

Advertising
background image

7-8

7.8

Scan Freq Menu

The Scan freq menu determines which DSC routine and distress frequencies to scan. Follow the
instructions below to select/deselect DSC routine and distress frequencies to scan.

7.8.1

Distress frequencies

1. Press the [#/SETUP] key, select SCAN FREQ and press the [ENT] key to display the SCAN

FREQ menu.

DISTRESS
2M :

FIXED

4M :

ON

6M : ON
8M :

FIXED

12M : ON
16M : OFF

**

Scan freq setup

*

ROUTINE

F1 :

2M-INTL

F2 : 4M-INTL
F3 : 6M-INTL
F4 : 8M-INTL
F5 : 16M-INTL
F6 : 25M-INTL

2. Press



to shift the cursor to the DISTRESS column.

3. Select the frequency to process and press the [ENT] key. For example, select 4 MHz.

ROUTINE
F1 : 2M-INTL
F2 : 2M-USR3
F3 : 4M-INTL
F4 : 8M-INTL
F5 : 16M-LCL1
F6 : 25M-LCL2

DISTRESS
2M :

FIXED

4M : ON

6M : ON
8M :

FIXED

12M : ON
16M : OFF

**

Scan freq setup

*

ON

OFF

4. Select ON or OFF as appropriate and press the [ENT] key.

5. Press the [CANCEL] key twice to return to the DSC standby screen.

Note: Regulations require that 2 MHz and 8 MHz be watched continuously. These frequencies
cannot be turned off. Maximum three bands may be turned off.

Advertising