3-7

3.4 Scan Channel Groups

The DP-6 can automatically control radio equipment through chan-
nel scanning. The radio equipment scans a number of channels
(according to your selection), stopping when your own ID code is
detected in an incoming signal. The transmitter is tuned to the cor-
responding transmitter frequency, the communication link is es-
tablished and the traffic is automatically exchanged. Scanning
resumes once the link is disconnected.

You may store a maximum of 10 scan groups, 20 channels per
group. Note that scanning is only possible in the ARQ and FEC
modes.

Registering Scan Channel Groups

1. Press function key [F5] followed by the [3] key to display the

Scan Entry screen.

Create

Change

Scan Entry

Scanning Group List

Scanning Set Up

Group Name

:

Ch Dwell Time : 4.5 sec (2.7-4.5 sec)

Mode

: AUTO ARQ FEC

Auto Search : OFF ON

No Channel Rx Freq Tx Freq Pass/Scan

1

2

3

4

5

6

Pass/Scan

Pass/Scan

Pass/Scan

Pass/Scan

Pass/Scan

Pass/Scan

Figure 3-8 Scan entry screen

2. If Create is not underlined, press [ ], [ ] and the [Enter] key

to underline it.

3. The cursor is on the Group Name line. Enter suitable group

name.

4. Press the [ ] key to advance the cursor to the CH Dwell Time

line. Enter channel dwell time in seconds. Dwell time is the
time in seconds the receiver waits on each channel in a scan
group before it selects the next frequency.