Probe name, Input type – YSI 5500D-1 User Manual

Page 53

Advertising
background image

YSI 5X00

105

YSI 5X00

104

5400 Configure Aux 5 menu

5500 Configure Aux 5 menu

(no Temp Source menu)

(

Temp Source menu will be available when Tempera-

ture

Input

Type

configured

Probe Name

Menus → System → Configure Aux →Aux 1-6→Probe Name

Use the alpha/numeric keypad to name aux inputs. Configured name(s) appear

throughout menus and at Run Screen - figure 4.7- page 108.

Note:

- Aux names can also be configured at Menus → System → Name Devices/

Sensors.

Input Type

Menus → System → Configure Aux →Aux 1-6→Input Type

→Digital

→0-1v

→0-5v

→4/20ma

→Aux 3-6→Input Type

→Temperature

Select the input type for the device(s) wired to aux system(s). Aux Sensor Setup

menu selections are based on the aux input type configured at system menu. Input

types are discussed in the following sections.

Configuring the 5X00

Digital

Menus → System → Configure Aux →Aux 1-6→Input Type→Digital

Use digital input when wiring an external device to control or alarm when the

contacts of an external switch open or close. A common application would be to

detect high or low water levels using a float switch.

Notes:

- Suffix, Min, Max, and Display Format are not available for digital inputs.

- In the 5X00 sensor log, aux digital “closed” is logged as Aux 0.00. Aux digital

“open” is logged as Aux 1.00.

1. Wire aux digital devices - page 59.

2. Enter Aux menu

Menus → System → Configure Aux →Aux 1-6

3.

Use

and

to scroll and highlight submenus.

4.

Press

to select.

5. Configure digital input type and name.
6. Press

to save configuration and return to Run Screen.

7. Go to Sensor Setup Menus → Sensor Setup Aux 1-6 - page 147 to

enable and configure control/alarm on condition, control/alarm relay,

and hold off time.

8. Press

to save configuration.

Analog Non Temperature

0-1VDC and 0-5VDC and 4-20 mA

Menus → System → Configure Aux →Aux 3-6→Input Type

→0-1V

→0-5V

→4/20ma

Select the analog input type based on the signal being sent from the device.

Configuring the 5X00