Sensors

Menus →Timers→Feed Smart Timer→Feeder→Sensors

→Disabled/Enabled

→DO Low/High/DO % Change

→Temp Low/High/Temp % Change

Changes in water conditions affect the amount of food fish eat which in turn affects

fish growth. With the sensor feature enabled, the feed timer system will verify that

DO and temperature values are within user configured ranges. This verification is

done immediately prior to starting each feed duration in a feed cycle. If values are

reported that fall outside acceptable configured ranges, the feed timer relay energizes

for a shorter period (user configured percentage) thereby reducing the amount of

food that is dispensed. Feed timer sensor ranges are independent of sensor setup

configuration ranges. For timed feed cycles, feed interval for the entire feed cycle

is determined by the duration of the first feed.

Example - The feed timer is configured as follows: sensor temperature low value

is 25.1oC, feed timer temperature change is 9%, timed feed mode, six feeds, daily

weight 2 units start time 8A, end time 9A, six 9.999 second feeds of .3333 units

each to occur at 9 minute 50 second intervals without sensor reduction. Prior

to 8A feed cycle, the start temperature value is reading 24.9oC. Feed duration of

9.999 seconds will be reduced by approximately 1 second (9%) because of the “out

of range” temperature value.

Notes:

- 5400 - Feed Timer temperature sensor value is always taken from the DO

system configured temperature source.

- Feed Timer temperature source is always taken from the ODO temperature

sensor regardless if temperature system is configured for an aux temperature

sensor.

DO Low/Temp Low

Enter the lower limit of the sensor range where no feed reduction will take place.

5400

5500

Configuring the 5X00

DO High/Temp High

Enter the high limit of the sensor range where no feed reduction will take place.

DO Change/Temp Change

Enter the percent reduction in feed weight that will occur for “out of range” enabled

feed timer sensors. Results from all out of range sensors are added. To disable a

sensor value from affecting feed duration configure 0.0% as the % change for that

sensor.

Calibrate

Menus →Timers→Feed Smart

tm

Timer→Feeder→Calibrate

Calibrating the feeder is essential for proper operation of the feed timer system.

Feed timer calibration is required to establish the amount of food dispensed over

a certain period of time. The 5X00 will base feed cycle duration times on the last

saved calibration value.

Calibrate Feed Smart

tm

Timer

1. Install and wire feed timer device. See wire relays - page 56.

2. Enable Feed Timer.

Menus → Timers→Feed Smart

tm

Timer →Feed Timer →Enabled

3. Assign feed timer relay.

Menus → Timers→Feed Smart

tm

Timer →Relay

4. Calibrate feeder.

Menus → Timers→Feed Smart

tm

Timer →Calibrate

5. At numeric keypad, enter test run time the feeder relay will energize.

Configuring the 5X00