Follower/follower setpoint p1/1 – CONTREX CX-1200 User Manual

Page 130

Advertising
background image

5 - 37

FOLLOWER/FOLLOWER SETPOINT P1/1

Run Mode

Run Mode (CP-202) sets the mode of operation and the subsequent Setpoint, that are used when your system is in
“Run”. The Setpoint and mode of operation combined, determine the Reference Speed and, if applicable, the
Reference Position. The modes of operation are:

4 = Inv Foll Mode
3 = Follower Mode
2 = Master Mode (default)
1 = Direct Mode

Sync Mode

Sync Mode (CP-203) selects the algorithm to be used when RUN Mode (CP-202) is set for Follower or Inverse Follower.
0 = Non-Sync Mode the position follower only, sync pulses are ignored by the control algorithm. 1 = Fixed Mode the
follower setpoint is the ratio/scale factor. 2 = Trend Mode the follower setpoint is altered by the control algorithm to
allow for continuously changing job sizes. 3 = Learn Mode learns the job spaces and the scale factor, also modifies the
follower setpoint.

3 = Learn
2 = Trend
1 = Fixed
0 = Off (default)

Follower SP

Follower Setpoint (CP-220) is the speed at which you want your system to operate (while in Run) when the Run Mode
(CP-202) is set to "3” (Follower Mode).

Min SP Fol

Minimum Setpoint Follower (CP-222) is a lower limit to the Master SP (CP-210). It will prevent lower entries in Master
SP (CP-210).

Max SP Fol

Maximum Setpoint Master (CP-221) is an upper limit to the Follower SP (CP-220). It will prevent higher entries in
Follower SP (CP-220).

Advertising