Cx-1200 appendix b, Appendix b: formulas – CONTREX CX-1200 User Manual

Page 341

Advertising
background image

B - 1

APPENDIX B: FORMULAS

(Continued)

The equations used to scale the Frequency Input 1 signal are given by:

MP-05 = MP-01 * CP-263 * X Seconds

s

CP-262 CP-209

written with parameter text:

Ld EU/Tm = FI1 Hz * EU FI1

1

* X Seconds

Pulses FI1 Time Base

where X = 1 for CP-209 = 0, None

X = 1 for CP-209 = 1, Second
X = 60 for CP-209 = 2, Minute
X = 3600 for CP-209 = 3, Hour

FI1 EU/Tm (MP-05) given in EU/Tm is multiplied by the ratio (given by CP-220) to obtain the desired speed in follower
applications.

MP-02 = MP-01 * 1 Rev * 60 Seconds

CP-261 Minute

written with parameter text:

FI1 RPM = FI1 Hz * 1 * 60 Seconds

PPR FI1 Minute

MP-10 = Lead Counts * CP-260 * CP-263

Count CP-262

written with parameter text:

Ld Posn = Lead Cnts * X Pulses (CP-260) * EU FI1

Count

Pulses FI1

where

X = 1 for CP-260 = 1, Quad (quadrature mode)
X = 4 for CP-260 = 2, Incr (incremental mode)

Keep in mind that the scaling is included in the ratio calculation for more accurate results. This further justifies using
integers when possible for the scaling numbers.