FUNCTION (08) DATA READ MAXIMUM PARAMETER VALUE

Table 32 CX-1200 Response

Character #

DESC

ASCII

STX

Msg Error

Separator

Parm #

Equals

Max Parm Value

ETX

1

2

3

4

5

6

7

^B

0-FF

,

1-999

=

<below>

^C

Max Parm Value Field

This field will contain an ASCII string Representation of the numeric maximum value for the param-
eter requested. If there is an error in the request, this field will contain the error code number pre-
ceded by an “E” (e.g., “E3”).