Appendix C: Parameter Summary Numeric Quick Reference (continued)

CP-201 Setpoint X

Setpoint X (CP-201) displays the name and value of the setpoint that corresponds with the mode of operation selected in
RUN Mode (CP-202). The setpoint could be the Master SP (CP-210), the Follower SP (CP-220) or the Direct SP (CP-230).
Setpoint X acts as a quick access to the setpoint value. In addition to changing a setpoint value in the setpoint
screens, you can also change the value of the active setpoint by entering a new value in Setpoint X (CP-201).

Minimum Value: -9999999

Maximum Value: 9999999

Default Value: 0.0

Units: EU/Tm

CP-202 Run Mode

Run Mode (CP-202) sets the mode of operation and the subsequent Setpoint, that are used when your system is in
“Run”. The Setpoint and mode of operation combined, determine the Reference Speed and, if applicable, the Reference
Position. The modes of operation are:

4 = Inv Foll Mode
3 = Follower Mode
2 = Master Mode (default)
1 = Direct Mode

Minimum Value: 1

Maximum Value: 4

Default Value: 2

Units: Coded

CP-203 Sync Mode

Sync Mode (CP-203) selects the algorithm to be used when RUN Mode (CP-202) is set for Follower or Inverse Follower.
0 = Non-Sync Mode the position follower only, sync pulses are ignored by the control algorithm. 1 = Fixed Mode the
follower setpoint is the ratio/scale factor. 2 = Trend Mode the follower setpoint is altered by the control algorithm to
allow for continuously changing job sizes. 3 = Learn Mode learns the job spaces and the scale factor, also modifies the
follower setpoint.

3 = Learn
2 = Trend
1 = Fixed (default)
0 = Off

Minimum Value: 0

Maximum Value: 3

Default Value: 0

Units: Coded

CP-204 Sync Logic

Sync Logic (CP-204) allows selection of the direction taken when making a sync-correction. Closest makes the correction
in the direction of the closest lead sync mark. Forward always makes the correction in the forward direction toward the
lead sync mark. And Back always makes the correction back to the lagging lead sync mark.

3 = Backward
2 = Forward
1 = Closest (default)

Minimum Value: 1

Maximum Value: 3

Default Value: 1

Units: Coded