INTRODUCTION TO

MONITOR PARAMETERS

Parameters are divided into two classifications; Control Parameters (CP) and Monitor Parameters (MP). This
section is about Monitor Parameters. Control Parameters are explained in System Setup/Control Parameters.

The parameters appear on the screens by a Parameter Name. The Help screens list the parameters by both
their name and by a numbered code, which is called the Parameter Code. The operational data is the
Parameter Value.

Parameters =

Monitor Parameter

Scaled Fb

MP-40

0.0 (default)

Control Parameter

Master

SP

CP-210

0.0 (default)

Parameter Name

Parameter Code

Parameter Value

Note:

Monitor Parameters are status indicators only - you can not directly affect or change a Monitor Parameter.
When Monitor Parameters are displayed on the screens, they do not have a small indicator “dot” to the left
of the Parameter Name (unlike Control Parameters, which do have a small indicator “dot” to the left of the
Parameter Name).

Monitor Parameter (MP) screens allow you to monitor the performance of the CX-1200 and your system.
These screens also help you troubleshoot for problems as well as confirm the wiring and tuning. Monitor
Parameter screens can be accessed at any time during the CX-1200's operation, including during Run, Jog
and F-Stop. The Monitor Parameter screens are accessed through the System Monitor screen.