Appendix C: Parameter Summary Numeric Quick Reference (continued)

MP-121 PLC 107-100

PLC 107-100 (MP-121) displays the status of PLC bits 107-100 (See graphic and list below). A “1” in any bit indicates
that the output is “active”. The digital outputs are active low (current sinking).

Digital Output 0

Digital Output 1

Digital Output 2

Digital Output 3

Digital Output 4

Digital Output 5

Digital Output 6

Digital Output 7

Bit Name

Description

Digital Output 0

Drive Enable

Digital Output 1

Batch Done

Digital Output 2

Sync Alarm

Digital Output 3

Fwd/Rvs

Digital Output 4

Lead Sync Absent

Digital Output 5

Foll Sync Absent

Digital Output 6

Hi/Low Speed Alarm

Digital Output 7

Zero Speed

Minimum Value: 00000000

Maximum Value: 11111111

Units: Coded

MP-122 PLC 115-108

PLC 115-108 (MP-122) displays the status of the internal PLC control bits 115-108 (See graphic below). A “1” in any bit
indicates that the bit is “active”. These internal bits (control relays) can be used as global “control relays”. For
example, they can be used to create one-shots or latches. They can also be used to simplify programming.

Temporary Bit 1

Temporary Bit 2

Temporary Bit 3

Temporary Bit 4

Temporary Bit 5

Temporary Bit 6

Temporary Bit 7

Temporary Bit 8

Minimum Value: 00000000

Maximum Value: 11111111

Units: Coded