CONTREX CX-1200 User Manual

Page 293

Advertising
background image

7 - 54

Table 65 Host Transmission

Byte #

DESC

Decimal

1

2

3

4

5

6

7

8

STX

Length

Address Function

Data

ETX

CRC

Hex

2

8

1-99

11

0-1

3

0-65535

02

08

01-63

0B

00-01

03

0000-FFFF

Data Field:

00 = Disable Data Trace Collection
01 = Enable Data Trace Collection and reset data pointers to the beginning, start collecting new data
and wait for a trigger point.

Message Length = 8 bytes

Table 66 CX-1200 Response

Byte #

DESC

Decimal

1

2

3

4

5

6

7

8

STX

Length

Address Msg Error Error Code

ETX

CRC

Hex

2

8

1-99

0-255

0-32

3

0-65535

02

08

01-63

00-FF

00-20

03

0000-FFFF

An Error Code of “00” indicates that the action was taken and was completed. Refer to page 7-53 for other
error code responses.

Message Length = 8 bytes

Advertising