Appendix B: Formulas (continued)

The equations used to scale the Auxiliary Analog Input 1 signal are given by:

MP-162 EU = SS_AIN2 * MP-161 + SI_AIN2

written with parameter text:

AI2 EU = SS_AIN2 * AI2 Signal + SI_AIN2

where

SS_AIN2 = CP-289 - CP-287 is the Scaling Slope

CP-288 - CP-286

written with parameter text:

SS_AIN2 = EU@AI2 RB - EU@AI2 RA

AI2 RB - AI2 RA

SI_AIN2 = CP-282 * CP-283 - CP-284 * CP-281 is the Scaling Intercept

CP-283 - CP-281

written with parameter text:

SI_AIN2 = EU@AI2 RA * AI2 RB - EU@AI2 RB * AI2 RA

AI2 RB - AI2 RA

and AI2 Signal (MP-164) is assumed to be a calibrated value.