CONTREX CX-1200 User Manual

Page 410

Advertising
background image

C - 64

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

CP-412 Tmr2 Delay

Timer 2 Delay (CP-412) is the time in seconds from which Timer 2 becomes enabled (Tmr2 En bit going from 0 to 1) until
the Tmr2 Out bit (25) in the PLC activated = 1. When the Tmr2 En bit (125) returns to “0”, the Tmr2 Out bit (25) is reset
to “0” and the delay-time is reset to “0”.

Minimum Value: 0

Maximum Value: 86400

Default Value: 1.000

Units: Seconds

CP-413 Tmr2 on Tm

Timer 2 on Time (CP-413) is the time, in seconds, from which Tmr 2 Out is activated (= 1) until Tmr2 Out is de-activated
(back to 0). When the Tmr2 En bit (125) returns to “0”, the Tmr2 Out bit (25) is reset = 0 and the on- time is reset to “0”.
If you want Tmr2 on-time to be infinite (“On” until Tmr2 is disabled with Tmr2 En = 0), then enter a value of -1 into Tmr2
on Tm (CP-413).

Minimum Value: -1

Maximum Value: 86400

Default Value: -1

Units: Seconds

CP-414 Tmr3 Delay

Timer 3 Delay (CP-414) is the time, in seconds, from which Timer 3 becomes enabled (Tmr3 En bit going from 0 to 1) until
the Tmr3 Out bit (26) in the PLC is activated = 1. When the Tmr3 En bit (126) returns to “0”, the Tmr3 Out bit (26) is
reset to “0” and the delay-time is reset to “0”.

Minimum Value: 0

Maximum Value: 86400

Default Value: 1.000

Units: Seconds

CP-415 Tmr3 on Tm

Timer 3 on Time (CP-415) is the time, in seconds, from which Tmr3 Out is activated (= 1) until Tmr3 Out is deactivated
(back to 0). When the Tmr3 En bit (126) returns to “0”, the Tmr3 Out bit (24) is reset = 0 and the on- time is reset to “0”.
If you want Timer 3 on-time to be infinite (“On” until Tmr3 is disabled with Tmr3 En = 0), then enter a value of -1 into
Tmr3 on Tm (CP-415).

Minimum Value: -1

Maximum Value: 86400

Default Value: -1

Units: Seconds

CP-416 Tmr4 Delay

Timer 4 Delay (CP-416) is the time, in seconds, from Timer 4 becoming enabled (Tmr4 En bit going from “0” to “1”)
toTmr4 Out bit (27) in the PLC going active = 1. If Tmr4 becomes disabled, the delay-time is retained so the timing can
continue when Tmr4 is re-enabled. The Tmr4Rst bit (128) in the PLC must be used to reset the delay time to “0”.

Minimum Value: 0

Maximum Value: 86400

Default Value: 1.000

Units: Seconds