5 - 40

STOP RAMPS P1/1

There are separate parameters that define the deceleration rate that is used for “R-Stop” and “H-Stop”.
However, Ref Ramps (CP-300) functions as the reference speed for both. Dcl Tm Rstp (CP-310) is the
time it would take to decelerate from the Reference Ramps speed to “0” for an “R-Stop”. Dcl Rt RStp (CP-
311) is the deceleration rate for “R-Stop”. Dcl Tm HStp (CP-312) is the time it would take to decelerate
from the Ref StopRmp speed to 0 for an “H-Stop”. Dcl Rt HStp (CP-313) is the deceleration rate for “H-
Stop”.

Ref Ramps

The acceleration rate for the application selected are determined by the Acl Tm RUN (CP-301) and the Ref Ramps (CP-
300). The deceleration rate (from a faster speed to a slower speed) for the application selected, are determined by the
Dcl Tm RUN (CP-303) and the Ref Ramps (CP-300).

Dcl Tm RStp

Deceleration Time R-Stop (CP-310) is the time, in seconds, that it takes to decelerate from the Ref Ramps (CP-300)
speed to 0, during R-Stop.

Dcl Rt RStp

Deceleration Rate R-Stop (CP-311) is the deceleration rate that is used for R-Stop.

Dcl Tm HStp

Deceleration Time H-Stop (CP-312) is the time, in seconds, that it takes to decelerate from the Ref Ramps (CP-300)
speed to 0, during H-Stop.

Dcl Rt HStp

Deceleration Rate H-Stop (CP-313) is the deceleration rate that is used for H-Stop.