Std signal tests / frequency inputs p1/2 – CONTREX CX-1200 User Manual

Page 306

Advertising
background image

8 - 9

STD SIGNAL TESTS / FREQUENCY INPUTS P1/2

The STD Signals Tests / Frequency Inputs screen (page 1) displays the Monitor Parameters that are
associated with FI1 Frequency Input and the FI2 Frequency Input. Input a known frequency and monitor
the results here.

FI1 Hz

Frequency Input 1 Hertz (MP-01) displays the current frequency of the Frequency Input 1, in Hertz.

FI1 RPM

Frequency Input 1 RPM (MP-02) displays the current speed of the Frequency Input 1 encoder in RPM, based on PPR
FI1 (CP-261).

FI1 EU/Tm

Frequency Input 1 Engineering Units per Time (MP-05) displays the current speed of the Frequency Input 1 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI1 (CP-262), EU FI1 (CP-263) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI1 (CP-263).

FI2 Hz

Frequency Input 2 Hz (MP-03) displays the current frequency of the Frequency Input 2, in Hertz.

FI2 RPM

Frequency Input 2 RPM (MP-04) displays the current speed of the Frequency Input 2 encoder in RPM, based on PPR
FI2 (CP-266).

FI2 EU/Tm

Frequency Input 2 Engineering Units per Time (MP-06) displays the current speed of the Frequency Input 2 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI2 (CP-267), EU FI2 (CP-268) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI2 (CP-268).

Advertising