CONTREX CX-1200 User Manual
Page 348
C - 2
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
MP-10 Ld Posn
Lead Position (MP-10) displays the present value of the Lead Position in Engineering Units, as specified by Pulses FI1
(CP-262) and EU FI1 (CP-263). The placement of the decimal point is the same as the placement of the decimal point in
EU FI1 (CP-263).
Minimum Value: 0
Maximum Value: 999999999
Units: EU
MP-11 LdJobSize
Lead Job Size (MP-11) displays the present value determined by the Lead Frequency and Lead Sync inputs. Displayed in
EU’s. It is the size of the very last job size that was encountered.
Minimum Value: 0
Maximum Value: 9999999
Units: EU
MP-12 LdJbSzVar
Lead Job Size Variance (MP-12) displays the maximum variance of the last 16 lead job sizes. Displayed in EU’s.
Minimum Value: -999999
Maximum Value: 999999
Units: EU
MP-13 LdJbSzAvg
Lead Job Size Average (MP-13) displays a running average value of the last 16 lead job sizes determined by the Lead
Frequency and Lead Sync inputs. Displayed in EU’s.
Minimum Value: 0
Maximum Value: 9999999
Units: EU
MP-14 LdJbSzAct
Lead Job Size Active (MP-14) displays a running average value of the last 16 qualifying lead job sizes determined by the
Lead Frequency and Lead Sync inputs. Displayed in EU’s. This is the job size currently being used by the control
algorithm.
Minimum Value: 0
Maximum Value: 9999999
Units: EU
MP-15 LdNetOfst
Lead Net Offset (MP-15) displays the resultant Net-Offset applied to the lead position after considering the LdSnsrDist
(CP-340) and the LdSnsrOfst (CP-341) values. LdNetOfst (MP-15) is the final resultant offset inside a lead job size.
Minimum Value: -999999
Maximum Value: 999999
Units: EU