C - 62

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

CP-403 DI Set

Digital Input Set (CP-403) simulates an “ACTIVE” condition on any or all of the PLC dedicated Digital Inputs (DI 15-8).
DI Set (CP-403) is logically OR’ed with the actual DI 15..8 (MP-101) bits to form the PLC 15-8 (MP-110) bits. The PLC 15-
8 (MP-110) bits are used by the PLC logic. The value of DI Set (CP-403) will not effect the actual DI 15..8 (MP-101) value,
rather, DI 15..8 (MP-101) reflects the present status of the actual inputs. Enter a “1” in a bit location to simulate an
active condition on the corresponding input. DI 15 to DI 8 get mapped into Bit 7 to Bit 0. Refer to the graphic below.

DI-8/Batch RST Cntr1

DI-9/Position Reset

DI-10/Re-Learn

DI-11/Phase Advance

DI-12/Phase Retard

DI-13/Block Select A

DI-14/Sync Disable

DI-15/Open Loop

Minimum Value: 00000000

Maximum Value: 11111111

Default Value: 00000000

Units: Coded

CP-405 PLC Monitor 1

PLC Monitor 1 (CP-405) determines which PLC bit will be monitored in PLC Mon 1 Val (MP-108). The PLC Mon 1 Val
(MP-108) displays the name of the bit rather than “PLC Mon 1 Val”. To select a PLC bit to monitor, enter the number of
the bit or by use the Scroll keys (^ or v) to scroll through the list. This bit can be monitored in any screen when the code
select line set to PLC Mon 1 Val (MP-108).

Minimum Value: 0

Maximum Value: 223

Default Value: 12

Units: PLC Bits