Appendix H: Error Code Definitions (continued)

(Continued)

Error

Definition

Minus First

When entering the value for this parameter the minus sign (-) must

be entered first.

No <END>

During compilation of the PLC program, no END command was

found.

No Cmpr Parm

Invalid comparison parameter entered.

Not Allowed

The last action attempted is not allowed.

Not Processd

The request for a parameter value change was not processed due to a

“combo” check error that occurred as a result of some calculation

for a related parameter value or a parameter in a block of

parameters. May be the result of a block parameter transfer to the

control via serial communications.

Not Ready

The control was “not ready” to process the last request.

NVRAM Failed

The memory test for the nonvolatile RAM has failed.

NVRAM Passed The memory test for the nonvolatile RAM has passed.

Only 1 Page

Occurs when the page up or page down key is pressed and there is

only one page to display.

Parm Mem Lmt

Indicates that the internal memory limit for parameters in block

parameters has been exceeded, and therefore the number of

parameters defined in block parameters must be reduced.

PLC BkUp set

Prompt to indicate that the PLC program has been changed to be the

same as the backup PLC program that was saved to backup.

PLC Dflt set

Prompt to indicate that the PLC program has been changed to be the

same as the default PLC program.

PLC Mem Lmt

During compilation of the PLC program, the internal memory limit

set for the PLC program has been exceeded. The PLC program

should be reduced.

Power Loss

Indicates that a momentary loss of AC power was detected.

Ratio too Hi

The ratio is too high.