Appendix C: Parameter Summary Numeric Quick Reference (continued)

MP-108 PLC Mon 1 Val

PLC Monitor 1 Value (MP-108) displays both the description and the value of the PLC bit that was selected in PLC
Monitor 1 (CP-405). Please note that a description of the PLC bit appears on the display line instead of the parameter
name (PLC Mon 1 Val).

Minimum Value: 0

Maximum Value: 1

Units: Coded

MP-109 PLC Mon 2 Val

PLC Monitor 2 Value (MP-109) displays both the description and the value of the PLC bit that was selected in PLC
Monitor 2 (CP-406). Please note that a description of the PLC bit appears on the display line instead of the parameter
name (PLC Mon 2 Val).

Minimum Value: 0

Maximum Value: 1

Units: Coded

MP-110 PLC 15-8

PLC 15-8 (MP-110) displays the status of PLC bits 15-8 (See graphic and list below). A “1” in any bit indicates that the
input is “active”. The digital inputs are active low.

Digital Input 8

Digital Input 9

Digital Input 10

Digital Input 11

Digital Input 12

Digital Input 13

Digital Input 14

Digital Input 15

Description

Default Function

Digital Input 8

Batch Reset

Digital Input 9

Position Reset

Digital Input 10

Re-Learn

Digital Input 11

Phase Advance

Digital Input 12

Phase Retard

Digital Input 13

Block Select A

Digital Input 14

Sync Disable

Digital Input 15

Open Loop

Minimum Value: 00000000

Maximum Value: 11111111

Units: Coded