Appendix C: Parameter Summary Numeric Quick Reference (continued)

MP-151 Misc Intrpt

Miscellaneous Interrupts (MP-151) displays a “1” in a bit to indicate which of the various system interrupts may have
caused the last reset.

Bus Error

Address Error

Illegal Instruction

Div by 0

Unimplemented Interrupt

General Exception

Not In Use

Not In Use

Minimum Value: 00000000

Maximum Value: 00111111

Units: Coded

MP-152 Device Alms

Device Alarms (MP-152) displays the status of microprocessor or other hardware related alarms. Notification of a bad
block selection is also included .

TPU FREQ1 Not Responding

TPU FREQ2 Not Responding

Low Power Alarm (per PLC and MP-54)

Bad Block Selected

Not In Use

Not In Use

Not In Use

Not In Use

Minimum Value: 00000000

Maximum Value: 00001111

Units: Coded

MP-153 PC at Intrpt

Program Counter at Interrupt (MP-153) shows where the last interrupt of the microprocessor occurred . If the CX-1200
repeatedly displays the “RESET FAULT” error box, then record the “PC @Intrpt” value as well as the line just above it
(which indicates the cause of the reset), before you press the clear key to continue. The program counter at interupt is
stored in the Program Counter at Interrupt (MP-153) Monitor Parameter for review. A value of “2560” is normal.

Minimum Value: 2560

Maximum Value: 524288

Units: Address