CP-380 Cmpr1 Parm

Enter a Monitor Parameter code in Compare 1 Parameter (CP-380) that will act on the value in Cmpr1 Val (CP-388), by
using the comparison type that you entered in Cmp1 Type (CP-384). If the comparison that is established by these three
parameters is “true”, then the PLC sets the Cmpr1 Out bit (60) in the PLC to “1”, which can be used to trigger a user
defined indicator.

Minimum Value: 1

Maximum Value: 199

Default Value: 32 (VelError)

Units: Parameter Code

NOTE: The following Monitor Parameters are not available for the Cmpr1 Parm (CP-380), Cmpr2 Parm (CP-381), Cmpr3

Parm (CP-382) or Cmpr4 Parm (CP-383):

MP-12 LdJobSpcVar

MP-13 LdJbSzAvg

MP-22 FbJobSpcVar

MP-23 FbJbSzAvg

MP-41 ScaleFactor

MP-42 ActScaleFactor

MP-49 Cntrl Loop

MP-52 InvalidBlks

MP-53 Misc Status

MP-54 Std Alarms

MP-55 Custom Alms

MP-56 Misc Alarms

MP-90 SerCom Char In

MP-91 SerCom Errs

MP-94 ROM Test

MP-95 SRAM Test

MP-96 NV RAM Test

MP-97 MODEL #

MP-98 RELEASE

MP-99 REVISION

MP-100 DI 7..0

MP-101 DI 15..8

MP-102 DO 7..0

MP-103 KeyPad Lockout

MP-108 PLC Mon 1 Val

MP-109 PLC Mon 2 Val

MP-110 PLC 15-8

MP-111 PLC 23-16

MP-112 PLC 31-24

MP-113 PLC 39-32

MP-114 PLC 47-40

MP-115 PLC 55-48

MP-116 PLC 63-56

MP-117 PLC 71-64

MP-118 PLC 79-72

MP-119 PLC 87-80

MP-120 PLC 95-88

MP-121 PLC 107-100

MP-122 PLC 115-108

MP-123 PLC 123-116

MP-124 PLC 131-124

MP-125 PLC 139-132

MP-126 PLC 147-140

MP-127 PLC 155-148

MP-128 PLC 163-156

MP-129 PLC 171-164

MP-130 PLC 179-172

MP-131 PLC 187-180

MP-132 PLC 195-188

MP-133 PLC 203-196

MP-134 PLC 211-204

MP-135 PLC 219-212

MP-150 Last Reset

MP-151 Misc Intrpt

MP-152 Device Alms

MP-153 PC at Intrpt

MP-156 Mem Err Cntr

MP-157 WatchDogCntr

MP-158 MiscIntrptCntr

MP-168 AnlgCal Ref A

MP-169 AnlgCal Ref B

MP-184 LdJSVarCnt

MP-194 FbJSVarCnt

CP-381 Cmpr2 Parm

Enter a Monitor Parameter code in Compare 2 Parameter (CP-381) that will act on the value in Cmpr2 Val (CP-389), by
using the comparison type that you entered in Cmp2 Type (CP-385). If the comparison that is established by these three
parameters is “true”, then the PLC sets the Cmpr2 Out bit (61) in the PLC to “1”, which can be used to trigger a user
defined indicator.

Minimum Value: 1

Maximum Value: 199

Default Value: 33 (PosnErr)

Units: Parameter Code

NOTE: Refer to the "NOTE" in CP-380.

CP-382 Cmpr3 Parm

Enter a Monitor Parameter in Compare 3 Parameter (CP-382) that will act on the value in Cmpr3 Val (CP-390), by using the
comparison type that you entered in Cmp3 Type (CP-386). If the comparison that is established by these three
parameters is “true”, then the PLC sets the Cmpr3 Out bit (62) in the PLC to “1” , which can be used to trigger a user
defined indicator.

Minimum Value: 1

Maximum Value: 199

Default Value: 37 (CO Volts)

Units: Parameter Code

NOTE: Refer to the "NOTE" in CP-380.