C - 71

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

CP-451 Diag DO Shift

When in Diagnostics State, Diagnostics Digital Out Shift (CP-451) may be used to activate the digital outputs one at a
time.

Warning: The actuator may energize if you change Diag DO (CP-452). Stand clear of the system.

8 = Zero Speed

Activated

7 = Hi/Low Spd Alm

Activated

6 = Foll Sync Absent

Activated

5 = Lead Sync Absent Activated
4 = Fwd/Rvs

Activated

3 = Sync Alarm

Activated

2 = Batch Done

Activated

1 = Drive Enable

Activated

0 = Off (default)

Minimum Value: 0

Maximum Value: 8

Default Value: 0

Units: Coded

CP-452 Diag DO

Diagnostic Digital Out (CP-452) controls the digital outputs when Diagnostics En (CP-450) is set to “1” (On or enabled)
during diagnostics. It is an 8 Bit Binary number with 1 bit per output. If the bit is a “1”, then the corresponding
output is pulled “low”. When you enter diagnostics, Diag DO (CP-452) is forced equal to the current DO 7..0 (MP-102)
so that there is no unexpected change in the outputs. Change the outputs through Diag DO (CP-452) while performing
the diagnostics.

Warning: The actuator may energize if you change Diag DO (CP-452). Stand clear of the system.

DO-0/Drive Enable

DO-1/Batch Done

DO-2/Sync Alarm

DO-3/Fwd/Rvs

DO-4/Lead Sync Absent

DO-5/Foll Sync Absent

DO-6/Hi/Low Speed Alarm

D-7/Zero Speed

Minimum Value: 00000000

Maximum Value: 11111111

Default Value: 00000000

Units: Coded