6 - 27

Sync Mode

Sync Mode (CP-203) selects the algorithm to be used when RUN Mode (CP-202) is set for Follower or Inverse Follower.
0 = Non-Sync Mode the position follower only, sync pulses are ignored by the control algorithm. 1 = Fixed Mode the
follower setpoint is the ratio/scale factor. 2 = Trend Mode the follower setpoint is altered by the control algorithm to
allow for continuously changing job sizes. 3 = Learn Mode learns the job spaces and the scale factor, also modifies the
follower setpoint.

3 = Learn
2 = Trend
1 = Fixed (default)
0 = Off

Cntrl Loop

Control Loop (MP-49) displays the present operating mode of the CX-1200. Only one type of loop can be active at a
time. These modes are automatically selected depending on the present system State (MP-50).

3 = Psn Hld (H-Stop Position Loop)
2 = Position Loop
1 = Velocity Loop
0 = Open Loop