H - 2

Error

Definition

Appendix H: Error Code Definitions (continued)

(Continued)

Halt Monitor

Reset caused by microprocessor or double bus fault.

Illegal Inst

Illegal Instruction.

Invalid Cmd

An invalid command was encountered during compilation of the

PLC program.

Invalid Opnd

An invalid operand was encountered during compilation of the PLC

program.

Invalid Parm

The parameter requested is not defined and therefore is invalid.

KyPd Lockout

The keypad is locked out, disallowing entry for this parameter

through the keypad.

LgWd Ovfl

There was a Long Word Overflow as a result of some internal

calculation.

LossOf Clock

There is no clock signal. Last reset caused by the detection of no

clock signal.

Low Power

The device’s AC input voltage level is low (below the required

specification).

Max Error

The parameter value just entered is above the maximum allowed for

the parameter.

Max Res Met

The maximum number of digits to the right of the decimal point for

the parameter being entered has already been met (an attempt was

made to exceed this limit).

Max SP Error

The value just entered for the setpoint exceeds the value set in its

corresponding Max SP (211,221).

Memory Fail

Indicates that a memory test has failed.

Memory Pass

Indicates that the memory test has passed.

Memory Error

An internal memory error was encountered.

Min Error

The parameter value last entered exceeded the minimum value

allowed for the parameter.

Min SP Error

The value just entered for the setpoint exceeds the value set in its

corresponding Min SP (212,222).