C - 61

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

CP-400 Rmt Scroll

In Remote Scroll (CP-400), enter the number of the Control Parameter that you want the Remote Scroll Up PLC bit (168) or
the Remote Scroll Dn PLC bit (169) to increment or decrement by 1 least significant digit, at the Rmt Scroll Rate (CP-401).
To disable the function, set Rmt Scroll (CP-400) to “0” .

Minimum Value: 0

Maximum Value: 449

Default Value: 351

Units: Parameter CP

CP-401 Rmt Scroll Rate

Remote Scroll Rate (CP-401) is the number of times per second, that the Control Parameter that you entered in Rmt Scroll
(CP-400) is either incremented or decremented by 1 least significant digit , when the Remote Scroll Up PLC bit (168) or
the Remote Scroll Dn PLC bit (169) is active.

Minimum Value: 1

Maximum Value: 100

Default Value: 10

Units: Increments/Decrements

CP-402 DI 1 Shot

Use the Digital Input 1 Shot (CP-402) to create a one scan pulse (one-shot) as the result of a high-to-low (open-to-
closed) transition on any or all of the PLC dedicated inputs. To generate a 1-scan pulse for an inactive high to an active
low transition, enter a “1” in the bit location of corresponding digital input. In the example below, the “1” has been
entered in Digital Input 9.

Digital Input 8

Digital Input 9

Digital Input 10

Digital Input 11

Digital Input 12

Digital Input 13

Digital Input 14

Digital Input 15

Minimum Value: 00000000

Maximum Value: 11111111

Default Value: 00000000

Units: Coded