CONTREX CX-1200 User Manual

Page 343

Advertising
background image

B - 3

Appendix B: Formulas (continued)

(Continued)

The equations used to scale the Auxiliary Analog Input 1 signal are given by:

MP-162 EU = SS_AIN1 * MP-164 + SI_AIN1

written with parameter text:

AI1 EU = SS_AIN1 * AI1 Signal + SI_AIN1

where

SS_AIN1 = CP-284 - CP-282 is the Scaling Slope

CP-283 - CP-281

written with parameter text:

SS_AIN1 = EU@AI1 RB - EU@AI1 RA

AI1 RB - AI1 RA

SI_AIN1 = CP-282 * CP-283 - CP-284 * CP-281 is the Scaling Intercept

CP-283 - CP-281

written with parameter text:

SI_AIN1 = EU@AI1 RA * AI1 RB - EU@AI1 RB * AI1 RA

AI1 RB - AI1 RA

and AI1 Signal (MP-161) is assumed to be a calibrated value.