Appendix C: Parameter Summary Numeric Quick Reference (continued)

Minimum Value: 1

Maximum Value: 2

Default Value: 1

Units: Coded

CP-266 PPR FI2

Pulses Per Revolution FI2 (CP-266) is the number of pulses that are produced during one revolution of the encoder (or
motor or any other rotating part of your machine) that is connected to Frequency Input 2. This value is only used to
calculate RPM information for FI2 RPM (MP-04).

Minimum Value: 1

Maximum Value: 60000

Default Value: 60

Units: Pulses/Rev

CP-267 FI2 Pulses

Frequency Input 2 Pulses (CP-267) is used to scale the Frequency Input 2 in EU’s and EU/Tm. Enter the number of
pulses that corresponds to the number of EU’s that are entered in EU FI2 (CP-268).

Minimum Value: 1

Maximum Value: 999999

Default Value: 60

Units: Pulses

CP-268 EU FI2

EU Frequency Input 2 (CP-268) is used to scale the Frequency Input 2 in EU’s and EU/Tm. Enter the number of EU's
that corresponds to the number of pulses that are entered in FI2 Pulses (CP-267).

Minimum Value: 0.0001

Maximum Value: 999999

Default Value: 1.0

Units: EU

CP-269 FbSyncPolarity

Feedback Sync Polarity (CP-269) is a selection that determines the polarity trigger direction of the Feedback Sync
pulses. The Feedback Sync input can be programmed to trigger on signals going from a low to high voltage level
(positive going) or from a high to low voltage level (negative going).

2 = Falling edge triggered (negative going)
1 = Rising edge triggered (positive going) (default)

Minimum Value: 1

Maximum Value: 2

Default Value: 1

Units: Coded

CP-270 CO Mode

Control Output Mode (CP-270) affects the range of Control Output (CO_Sig) analog signal sent out to the drive.

3 = Unipolar Reversible
2 = Bipolar (default)
1 = Unipolar