C - 66

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

CP-425 Cntr3 Cnt

Counter 3 Count (CP-425) is the current count for “Counter 3”. The CX-1200 automatically increments it one count for
every “0” to “1” transition of the Cntr3 Inc bit (132). Either use the Scroll keys or enter a new number to change this
value. When the PLC program sets Cntr3 Rst bit (137) to “1”, then the Cntr3 Cnt (CP-425) resets to “0” .

Minimum Value: 0

Maximum Value: 10000000

Default Value: 0

Units: Counts

CP-426 Cntr4TrigUp

When Cntr4 Cnt (CP-427) is greater than or equal to Counter 4 Trigger Up (CP-426), then the Cntr4 UpOut bit (35) in the
PLC is set to “1”. If the count is less than, the Counter 4 Trigger Up, the Cntr4UpO bit (35) will be “0”.

Minimum Value: 0

Maximum Value: 10000000

Default Value: 10

Units: Counts

CP-427 Cntr4Cnt

Counter 4 Count (CP-427) is the current count for “Counter 4”. The CX-1200 automatically increments it one count for
every “0” to “1” transition of the Cntr4 Inc bit (133). The CX-1200automatically decrements it one count for every “0”
to “1” transition of the Cntr Dec bit (134). Either use the Scroll keys or enter a new number to change this value. When
the PLC program sets Cntr4 Rst bit (138) to “1”, then the Cntr4 Cnt (CP-427) resets to the value of Cntr4Preset (CP-429).

Minimum Value: 0

Maximum Value: 10000000

Default Value: 0

Units: Counts

CP-428 Cntr4TrigDn

When Cntr4 Cnt (CP-427) is less than or equal to Counter 4 Trigger Down (CP-428), then the Cntr4DnO bit (36) in the
PLC is set to “1”. If the count is less than, the Counter 4 Trigger Down, the Cntr4 DnO bit (36) will be “0”.

Minimum Value: 0

Maximum Value: 10000000

Default Value: 0

Units: Counts

CP-429 Cntr4Preset

When the Cntr4 Rst bit in the PLC Programming screen is set to “ 1”, then Cntr4 Cnt (CP-327) is set to and held at the
Counter 4 Preset (CP-429) value. If you need a transition preset , then create a one-shot or, when possible, use the DI 1
Shot (CP-402) mask.

Minimum Value: 0

Maximum Value: 10000000

Default Value: 0

Units: Counts

CP-430 DN Write Parm 1

Enter the number of a Control Parameter to be written to with the DeviceNet poll command in the I/O Assembly Queue.

Minimum Value: 0

Maximum Value: 667

Default Value: 0

Units: CP