D - 4

USER

CODE

DESCRIPTION

MIN

MAX

DEFAULT

RECORD

UNITS

CP-360

Loop Update

1

3

1

Coded

CP-361

Sig Fltr

0

4

0

Coded

CP-362

SigFltrTmConst

2

500

10

mSec

CP-363

KffAdjUpdt

1

6

3

Coded

CP-364

Kff Auto En

0

1

0

Coded

CP-367

LgErrThld

0

999999

999999

EU

CP-368

LgErrGain

1

100

20

%/Sec

CP-369

OvrSpdAllow

1

100

50

%

CP-370

Min Fb Alm

0

9999999

0

EU/Tm

CP-371

Max Fb Alm

0

9999999

2000

EU/Tm

CP-372

Max Acl/Dcl

0

9999999

2000

EU/Sec

2

CP-373

NO Resp Time

0.010

600

1.000

Seconds

CP-374

Posn Alarm

0.001

9999999

999999

EU/Tm

CP-375

Std Alm Msk

00000000

11111111

00000000

Coded

CP-376

CustAlm Msk

00000000

11111111

00000000

Coded

CP-380

Cmpr1 Parm

1

199

32

MP

CP-381

Cmpr2 Parm

1

199

33

MP

CP-382

Cmpr3 Parm

1

199

37

MP

CP-383

Cmpr4 Parm

1

199

36

MP

CP-384

Cmpr1 Type

1

6

4

Coded

CP-385

Cmpr2 Type

1

6

4

Coded

CP-386

Cmpr3 Type

1

6

5

Coded

CP-387

Cmpr4 Type

1

6

5

Coded

CP-388

Cmpr1 Val

-9999999

9999999

2000

Parm Val

CP-389

Cmpr2 Val

-9999999

9999999

1000

Parm Val

CP-390

Cmpr3 Val

-9999999

9999999

15

Parm Val

CP-391

Cmpr4 Val

-9999999

9999999

7.5

Parm Val

CP-396

Copy Source 1

1

667

230

CP or MP

CP-397

Copy Dest 1

201

667

230

CP or MP

CP-398

Copy Source 2

1

667

230

CP or MP