Componet (3) i/o signal assignment – IAI America PCON-CFA User Manual

Page 104

Advertising
background image

3. SCON-CA/CF

A


98

CompoNet

(3)

I/O signal assignment

The controller's I/O port signal varies depending on the parameter No. 25 setting.
(Refer to Operation Manual for the controller main body for more information.)

Parameter No. 25 setting

Positioning mode

Teaching mode

256-point mode

0 1 2

Category

Port

No.

Symbol

Signal Name

Symbol

Signal Name

Symbol

Signal Name

0

PC1

PC1

PC1

Command position No.

1 PC2

PC2

PC2

2 PC4

PC4

PC4

3 PC8

PC8

PC8

4 PC16

PC16

PC16

5 PC32

Command position No.

PC32

Command position No.

PC32

6 -

MODE

Teaching Mode

Command

PC64

7 -

JISL

Jog/inching

selector

PC128

8 -

Unavailable

JOG+ +Jog

- Unavailable

9

BKRL

Forced brake release

JOG-

-Jog

BKRL

Forced brake release

10

RMOD

Operating mode selector

RMOD

Operating mode selector

RMOD

Operating mode selector

11

HOME

Home return

HOME

Home return

HOME

Home return

12 *STP

Pause

*STP

Pause

*STP

Pause

13 CSTR Positioning

Start

CSTR/
PWRT

Positioning Start/

Position Data Import

Command

CSTR Positioning

Start

14 RES

Reset

RES

Reset

RES

Reset

PLC Output

ĺ

PCON

-CA/CFA

Input

15

SON

Servo ON Command

SON

Servo ON Command

SON

Servo ON Command

0

PM1

PM1

PM1

Completed Position No.

1 PM2

PM2

PM2

2 PM4

PM4

PM4

3 PM8

PM8

PM8

4 PM16

PM16

PM16

5 PM32

Completed Position No.

PM32

Completed Position No.

PM32

6

MOVE

Moving Signal

MOVE

Moving Signal

PM64

7

ZONE1

Zone 1

MODES

Teaching mode Signal

PM128

8

PZONE/

PZONE2

Position zone/zone2

PZONE/

PZONE1

Position zone/zone1

PZONE/

PZONE1

Position zone/zone1

9

RMDS

Operation Mode Status

RMDS

Operation Mode Status

RMDS

Operation Mode Status

10

HEND

Home return completion

HEND

Home return completion

HEND

Home return completion

11

PEND/
WEND

Positioning completion

signal

PEND

Positioning completion

signal/

position-data read

complete

Positioning
completion

signal

12 SV

Operation preparation

end

SV

Operation preparation

end

SV

Operation preparation

end

13

*EMGS

Emergency stop

*EMGS

Emergency stop

*EMGS

Emergency stop

14 *ALM

Alarm

*ALM

Alarm

*ALM

Alarm

PCON

-CA/CFA

Output

ĺ

PLC Input

15

LOAD/
TRQS/
*ALML

Load output judgment/

Torque level/

Light error status

*ALML

Light error status

LOAD/
TRQS/
*ALML

Load output judgment/

Torque level/

Light error status

The symbol with a * mark shows the ON signal in normal condition.

The signal described as “Unavailable” is not controlled. (ON/OFF is undefined.)