4. SCON-CA


211

CompoNet


4.7.8

Half Direct Value Mode (Number of occupied channels

8CH)


In this mode, the actuator is operated by means of force control (push-motion operation based on feedback of
load cell values) and also by specifying the target position, positioning band, speed, acceleration/deceleration
and push current directly as numerical values. Set each value in the I/O areas. When the zone function is used,
set it using the parameter Nos. 1, 2, 23 and 24.

The robot cylinder's effective main functions that can be controlled using this mode, are as shown in the
following table.

ROBO cylinder function

{:Direct control

ٌ:Indirect control
x:Disable

Remark

Home-return operation

{

Positioning operation

{

Speed and acceleration /
deceleration setting

{

Pitch feed (inching)

{

Pressing Operation

{

Speed change during the
movement

{

Operation at different
acceleration and deceleration

x

Pause

{

Zone signal output

ٌ

Parameters must be set.

PIO pattern selection

x

(1)

PLC channel configuration (* “n” shows the node address of each axis.)

Parameter

No.84

SCON-CA input register

PLC output

CH

SCON-CA output

register

PLC input

CH

n+0

n+0

Target Position

n+1

Current Position

n+1

n+2

n+2

Positioning Band

n+3

Force feedback data

n+3

6 Velocity n+4

n+4

Acceleration/

Deceleration

n+5

Current Speed

n+5

Pressing Current Limit

Value

n+6 Alarm

Code n+6

Control signal

n+7

Status Signal

n+7

(Note) Be careful of using duplicated node addresses.