2. ACON-C/CG,

PCON-C/CG


51

CompoNet

(3)

I/O signal assignment

For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assignments for the remote
I/O mode explained in 2.7.2 (3).

The signal allocation for the Command Current and Current Position, is shown in the following table.

Signal Type

Bit

Symbol

Contents

Details

Current

Position

32-bit data

-

32-bit signed integer indicating the current position
The setting unit is 0.01mm.
(Example) Reading:000003FF

H

=1023 (decimal)

=10.23mm

* When the value is read in hexadecimal notation, the

negative figure is expressed as a complement of 2.

-

PLC Input

Command

Current

32-bit data

-

32-bit integer
The value of electrical current specified by the current
command is indicated.
The setting unit is 1mA.
(Example) Reading:000003FF

H

=1023 (decimal)

=1023mA

-