4. SCON-CA


176

CompoNet


(3)

I/O signal assignment

The controller's I/O port signal varies depending on the parameter No. 25 setting.
(Refer to Operation Manual for the controller main body for more information.)

Parameter No. 25 setting

Positioning mode

Teaching mode

256-point mode

0 1 2

Category

Port No.

Symbol

Signal Name

Symbol

Signal Name

Symbol

Signal Name

0 PC1

PC1

PC1

1 PC2

PC2

PC2

2 PC4

PC4

PC4

3 PC8

PC8

PC8

4 PC16

PC16

PC16

5 PC32

Command position No.

PC32

Command position No.

PC32

6

-

MODE

Teaching Mode Command

PC64

7 -

JISL

Jog/inching

selector

PC128

Command position No.

8 -

Unavailable

JOG+ +Jog

- Unavailable

9

BKRL

Forced brake release

JOG-

-Jog

BKRL

Forced brake release

10 RMOD Operating

mode

selector RMOD Operating

mode

selector RMOD Operating

mode

selector

11

HOME

Home return

HOME

Home return

HOME

Home return

12

*STP Pause *STP Pause *STP Pause

13 CSTR

Positioning

Start

CSTR/
PWRT

Positioning Start/ Position

Data Import Command

CSTR Positioning

Start

14

RES Reset RES Reset RES Reset

PLC Output

ψ

SCON Input

15

SON

Servo ON Command

SON

Servo ON Command

SON

Servo ON Command

0 PM1

PM1

PM1

1 PM2

PM2

PM2

2 PM4

PM4

PM4

3 PM8

PM8

PM8

4 PM16

PM16

PM16

5 PM32

Completed Position No.

PM32

Completed Position No.

PM32

6

MOVE Moving

Signal MOVE Moving

Signal PM64

7

ZONE1

Zone 1

MODES

Teaching mode Signal

PM128

Completed Position No.

8

PZONE/

ZONE2

Position zone/

Zone 2

PZONE/

ZONE1

Position zone/

Zone 1

PZONE/

ZONE1

Position zone/

Zone 1

9

RMDS

Operation Mode Status

RMDS

Operation Mode Status

RMDS

Operation Mode Status

10 HEND Home

return

completion HEND Home

return

completion HEND Home

return

completion

11

PEND

Positioning completion signal

PEND/
WEND

Positioning completion

signal/

position-data read complete

PEND

Positioning completion signal

12

SV

Operation preparation end

SV

Operation preparation end

SV

Operation preparation end

13

*EMGS Emergency

stop *EMGS Emergency

stop *EMGS Emergency

stop

14

*ALM Alarm *ALM Alarm *ALM Alarm

SCON Output

ψ

PLC Input

15

*BALM Battery

alarm *BALM Battery

alarm *BALM Battery

alarm

The symbol with a * mark shows the ON signal in normal condition.
The signal described as “Unavailable” is not controlled. (ON/OFF is undefined.)

Advertising