4. SCON-CA


191

CompoNet

4.7.5

Full Direct Value Mode (Number of occupied channels

16CH)


This is the operation mode with all the values (target position, speed, etc.) set up directly using values from PLC.
Set each value in the I/O area.

The robot cylinder's effective main functions that can be controlled using this mode, are as shown in the
following table.

ROBO cylinder function

{:Direct control
x:Disable

Home-return operation

{

Positioning operation

{

Speed and acceleration /
deceleration setting

{

Pitch feed (inching)

{

Pressing Operation

{

Speed change during the movement

{

Operation at different acceleration
and deceleration

{

Pause

{

Zone signal output

{

PIO pattern selection

x

(1)

PLC channel configuration (* “n” shows the node address of each axis.)

Parameter

No. 84

SCON-CA input

register

PLC output address

SCON-CA output

register

PLC input address

n+0 n+0

Target position

n+1

Current position

n+1

n+2 n+2

Positioning band

n+3

Command current

n+3

n+4 n+4

Speed

n+5

Current speed

n+5

n+6 Alarm

code n+6

Zone boundary+

n+7

Occupied area

n+7

n+8 n+8

Zone boundary-

n+9

Force feedback data

n+9

Acceleration n+10

n+10

Deceleration n+11

Total moving count

n+11

Push-current limiting

value

n+12 n+12

Load current threshold

n+13

Total moving distance

n+13

Control signal 1

n+14

Status signal 1

n+14

3

Control signal 2

n+15

Status signal 2

n+15


(Note)

The areas denoted by Occupied area cannot be used for any other purpose.

Also, exercise caution to avoid node address duplication.