IAI America PCON-CFA User Manual

Page 189

Advertising
background image

4. SCON-CA


183

CompoNet

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit

Symbol

Contents

Details

Current

Position

32-bit

-

Current Position: 32-bit signed Integer.
The setting unit is 0.01mm.
(Example)
Reading:000003FF

H

=1023 (decimal)=10.23mm

* When the value is read in hexadecimal notation, the negative figure

is expressed as a complement of 2.

4.9 (1)

Completed

Position No.

(Simple

alarm
code)

16-bit

PM1 to
PM512

16-bit integer
It is moved to the target position and the positioning completed
position No. within the positioning band is output.
In the case that the position movement has not been performed at all,
or during the movement, “0” is output.
When an alarm is issued (in the case that the status signal ALM is
“ON”), the simplified alarm code (Refer to the Operation Manual for the
controller main body) is output.

4.9 (1)

b15 EMGS

Emergency stop: An emergency stop is actuated when this signal
turns ON.

4.7.11 (2)

b14 PWR

Controller ready : This signal turns ON when the controller becomes
ready.

4.7.11 (1)

b13

ZONE2 Zone 2:“ON” for the current position within the zone set range

4.7.11 (12)

b12

ZONE1 Zone 1:“ON” for the current position within the zone set range

4.7.11 (12)

b11

PZONE

Position zone:
This signal turns ON when the current position is inside the specified
position zone.

4.7.11 (12)

b10

MODES

Teaching mode Signal: This signal is ON while the teaching mode is
selected.

4.7.11 (16)

b9 WEND

Position-data read complete : This signal turns ON when reading is
complete.

4.7.11 (17)

b8 RMDS

Operation Mode Status:
This signal is OFF when the current mode is AUTO, or ON when the
current mode is MANU.

4.7.11 (19)

b7

BALM

Absolute battery voltage low warning: This signal turns ON when the
voltage drops.

4.7.11 (28)

b6 -

Unavailable

-

b5 PSEL

Pressing and a Miss: This signal turns ON when the actuator missed
the load in push-motion operation.

4.7.11 (23)

b4 SV

Operation preparation end: This signal turns ON when the servo turns
ON.

4.7.11 (5)

b3 ALM

Alarm:

This signal turns ON when an alarm occurs. 4.7.11

(3)

b2

MOVE Moving Signal: This signal remains ON while the actuator is moving.

4.7.11 (9)

b1 HEND

Home return completion: This signal turns ON when home return is
completed.

4.7.11 (6)

PLC Input

Status

code

b0 PEND

Positioning completion signal: This signal turns ON when positioning is
completed.

4.7.11 (10)

Advertising