IAI America PCON-CFA User Manual

Page 45

Advertising
background image

2. ACON-C/CG,

PCON-C/CG


39

CompoNet

2.7.5

Full Direct Value Mode (Number of occupied channels

16CH)


This is the operation mode with all the values (target position, speed, etc.) set up directly using values from PLC.
Set each value in the I/O area.

The robot cylinder's effective main functions that can be controlled using this mode, are as shown in the
following table.

ROBO cylinder function

{:Direct control
x:Disable

Home-return operation

{

Positioning operation

{

Speed and acceleration / deceleration
setting

{

Pitch feed (inching)

{

Pressing Operation

{

Speed change during the movement

{

Operation at different acceleration and
deceleration

{

Pause

{

Zone signal output

{

PIO pattern selection

x

(1)

PLC channel configuration (* “n” shows the node address of each axis.)

ParameterNo.84 ACON/PCON input register

PLC output CH ACON/PCON output register

PLC input

CH

n+0

n+0

Target Position

n+1

Current Position

n+1

n+2

n+2

Positioning Band

n+3

Command Current

n+3

n+4

n+4

Velocity

n+5

Current Speed

n+5

n+6

Alarm

Code

n+6

3

Zone boundary +

n+7

n+7

n+8

n+8

Zone boundary -

n+9

n+9

Acceleration

n+10

n+10

Deceleration

n+11

n+11

Pressing Current Limit Value

n+12

n+12

ACON

Occupied area

PCON

Load current

threshold

n+13

n+13

Control Signal 1

n+14

Occupied area

n+14

Control Signal 2

n+15

Status Signal

n+15


(Note)

The areas denoted by Occupied area cannot be used for any other purpose.

Also, exercise caution to avoid node address duplication.