IAI America PCON-CFA User Manual

Page 48

Advertising
background image

2. ACON-C/CG,

PCON-C/CG


42

CompoNet


Channel (* “n” shows the node address of each axis.)

Zone boundary –

(upper word)

(lower word)

Zone boundary –

1 word (1CH) = 16 bits

When the zone boundary is shown using the negative figure, it is expressed using the
complement of 2.

Acceleration

Deceleration

Pressing

Current

Limit Value

Control
Signal 1

Load current

threshold

( *3)

Control
Signal 2

(*

1

)

(*

2

)


(*1) Signal assignment for b10 of n+14

(*2) Signal assignment for b7 and b6 of n+14

Symbol

Symbol

Controller ACON PCON Controller ACON

PCON

b10 -

SMOD

b7

MOD1

-

b6

MOD0

-

(*3) This is a dedicated function for PCON controllers. It is not available with ACON controllers.

ASO1

ASO0

Advertising
This manual is related to the following products: