4. SCON-CA


203

CompoNet

(1)

PLC channel configuration (* “n” shows the node address of each axis.)

Parameter

No. 84

SCON-CA DI and input

register

PLC output address

SCON-CA DO and

output register

PLC input address

Port number 0 to 15

n+0

Port number 0 to 15

n+0

n+1

Occupied area

n+1

n+2 n+2
n+3

Current position

n+3

n+4 n+4

4

Occupied area

n+5

Command current

n+5

(Note) The areas denoted by Occupied area cannot be used for any other purpose.

Also, exercise caution to avoid node address duplication.

(2)

I/O Signal Allocation for each Axis

The I/O signals of each axis consist of 6 input words (channels) and 6 output words (channels) in the I/O areas.

z The areas controlled by port number are controlled using ON/OFF bit signals.

z The current position is a 2-word (32-bit) binary data (unit: 0.01 mm).

z The command current is expressed using 2-word (32 bits) binary data (Unit: 1mA).