IAI America PCON-CFA User Manual

Page 250

Advertising
background image

4. SCON-CA


244

CompoNet

(31) Standstill Mode Selection (ASO0, ASO1) PLC Output Signals

Select the stop mode to be applied while the actuator is standing by to move to the next position after completing
a positioning.
If the actuator remains standstill for a long time, the servo is turned off automatically to lower the power
consumption.
For details, refer to the operation manual for your controller.

ASO1 ASO0

Functions

Remarks

OFF OFF

Disabled

Factory

setting

OFF ON

Automatic servo OFF method
Parameter No. 36 is enabled for T in the figure below.

ON OFF

Automatic servo OFF method
Parameter No. 37 is enabled for T in the figure below.

ON ON

Automatic servo OFF method
Parameter No. 38 is enabled for T in the figure below.



















Movement command


Servo status


Actuator movement

Servo ON status

Auto servo OFF mode

(A green LED blinks.)

Delay time until the servo turns off after
completion of positioning (sec)

Target position

Advertising