3. SCON-CA/CF

A


112

CompoNet

3.7.5

Full Direct Value Mode (Number of occupied channels

16CH)


This is the operation mode with all the values (target position, speed, etc.) set up directly using values from PLC.
Set each value in the I/O area.

The robot cylinder's effective main functions that can be controlled using this mode, are as shown in the
following table.

ROBO cylinder function

{:Direct control
x:Disable

Home-return operation

{

Positioning operation

{

Speed and acceleration / deceleration
setting

{

Pitch feed (inching)

{

Pressing Operation

{

Speed change during the movement

{

Operation at different acceleration and
deceleration

{

Pause

{

Zone signal output

{

PIO pattern selection

x

(1)

PLC channel configuration (* “n” shows the node address of each axis.)

ParameterNo.84

PCON-CA/CFA

input register

PLC output CH

PCON-CA/CFA

output register

PLC input

CH

n+0 n+0

Target Position

n+1

Current Position

n+1

n+2 n+2

Positioning Band

n+3

Command Current

N+3

n+4 n+4

Velocity

n+5

Current Speed

n+5

n+6 Alarm

Code n+6

Zone boundary +

n+7

n+7

n+8

n+8

Zone boundary -

n+9

Occupied area

n+9

Acceleration n+10

n+10

Deceleration n+11

Total moving count

n+11

Pressing Current Limit Value

n+12

n+12

Load current threshold

n+13

Total moving distance

n+13

Control Signal 1

n+14

Status Signal 1

n+14

3

Control Signal 2

n+15

Status Signal 2

n+15


(Note)

The areas denoted by Occupied area cannot be used for any other purpose.

Also, exercise caution to avoid node address duplication.