Componet – IAI America PCON-CFA User Manual

Page 183

Advertising
background image

4. SCON-CA


177

CompoNet

Parameter No. 25 setting

512-point mode

Electromagnetic valve mode 1

Electromagnetic valve mode 2

3 4 5

Category

Port No.

Symbol

Signal Name

Symbol

Signal Name

Symbol

Signal Name

0

PC1

ST0

Start position 0

ST0

Start position 0

1

PC2

ST1

Start position 1

ST1

Start position 1

2

PC4

ST2

Start position 2

ST2

Start position 2

3

PC8

ST3

Start position 3

-

4

PC16

ST4

Start position 4

-

5

PC32

ST5

Start position 5

-

6

PC64

ST6

Start position 6

-

7 PC128

-

-

8 PC256

Command position No.

-

Unavailable

-

Unavailable

9

BKRL

Forced brake release

BKRL

Forced brake release

BKRL

Forced brake release

10

RMOD

Operating mode selector

RMOD

Operating mode selector

RMOD

Operating mode selector

11

HOME

Home return

HOME

Home return

-

12 *STP

Pause

*STP

Pause

-

13 CSTR Positioning

Start

-

Unavailable

-

Unavailable

14

RES Reset RES Reset RES Reset

PLC Output

ĺ

SCON Input

15 SON Servo

ON

Command SON Servo

ON

Command SON Servo

ON

Command

0

PM1

PE0

Position 0 complete

LS0

Retracting end

movement command 0

1

PM2

PE1

Position 1 complete

LS1

Retracting end

movement command 1

2

PM4

PE2

Position 2 complete

LS2

Retracting end

movement command 2

3

PM8

PE3

Position 3 complete

-

4

PM16

PE4

Position 4 complete

-

5

PM32

PE5

Position 5 complete

-

6

PM64

PE6

Position 6 complete

-

Unavailable

7

PM128

ZONE1

Zone

1 ZONE1 Zone

1

8 PM256

Completed Position No.

PZONE/

ZONE2

Position zone/

Zone 2

PZONE/

ZONE2

Position zone/

Zone 2

9

RMDS

Operation Mode Status

RMDS

Operation Mode Status

RMDS

Operation Mode Status

10

HEND

Home return completion

HEND

Home return completion

HEND

Home return completion

11 PEND

Positioning completion

signal

PEND

Positioning completion

signal

- Unavailable

12 SV

Operation preparation

end

SV

Operation preparation

end

SV

Operation preparation

end

13

*EMGS Emergency

stop *EMGS

Emergency

stop *EMGS Emergency

stop

14

*ALM Alarm *ALM Alarm *ALM Alarm

SCON Output

ĺ

PLC Input

15

*BALM

Battery alarm

*BALM

Battery alarm

*BALM

Battery alarm

The symbol with a * mark shows the ON signal in normal condition.
The signal described as “Unavailable” is not controlled.(ON/OFF is undefined.)