IAI America PCON-CFA User Manual

Page 164

Advertising
background image

3. SCON-CA/CF

A


158

CompoNet


[2] If the alarm is occurred, checking the network status on the display of monitor LEDs is possible.

{: Illuminating, x: OFF, ᧙: Flashing

MS NS

Item

Cause of error occurrence

Unit operation after

error detection

Measure

x

-

No power
supply input

Specified power voltage is not
supplied.

PCON stop the
operation.

Remove the cause of no power supply
input and input the power supply again.

{

GN

ڏ

RD

Communication
Error

Remote I/O communication that
the connection was set up with
the master unit has stopped by
timeout.

PCON continue the
operation.

The following cases are considered to be
the possible causes of communication
error. Find the most suitable case and
remove the cause.
1) A stop was cased by an error on the

PLC system including the master unit.

ψ Check the PLC system condition
and cancel the error.

2) Communication with the master unit is

disabled by broken connector,
repeater, etc.

ψ Check the conditions of cables,
terminals and repeater.

Supply the communication power

again after an error cause is removed.

3) Master unit stopped the

communication due to the
communication retries with the
applicable PCON continuously
exceeded the specified value caused
by noise.

ψ Check the noise condition around
the applicable PCON


For the items above excluding 1) restart
of master unit is not necessary.

{

GN

{

RD

Address
duplication
error

There is PCON with the same
node existing on the network.

PCON stop the
operation.

Confirm the node number of PCON,
correct the duplicated number, then
conduct operations in the following
procedure.
1) Turn OFF the communication power

supply between the master unit and
PCON.

2) Turn ON the communication power

supply between the master unit and
PCON again.

{

RD

- Unit

error

An error has occurred to PCON
due to the following causes.

PCON stop the
operation.

Check the set value for the node
address to remove the possibility of the
error cause for 1).
Then, restart (turn on the communication
power supply again) PCON.
If the error occurs again, replace PCON.

Advertising
This manual is related to the following products: