Componet – IAI America PCON-CFA User Manual

Page 128

Advertising
background image

3. SCON-CA/CF

A


122

CompoNet

b15

EMGS

Emergency stop: An emergency stop is actuated when this signal turns ON.

3.7.7 (2)

b14

PWR

Controller ready : This signal turns ON when the controller becomes ready.

3.7.7 (1)

b13

ZONE2

Zone 2:“ON” for the current position within the zone set range

3.7.7 (12)

b12

ZONE1

Zone 1:“ON” for the current position within the zone set range

3.7.7 (12)

b11

PZONE

Position zone:
This signal turns ON when the current position is inside the specified position zone.

3.7.7 (12)

b10 LOAD

Load Output Judgment:
“ON” for Reached “OFF” for Not reached
[Refer to the instruction manual for the controller main body for more
information.]

3.7.7 (26)

b9 TRQS

Torque Level:
“ON” for Reached “OFF” for Not Reached
[Refer to the instruction manual for the controller main body for more
information.]

3.7.7 (27)

b8 RMDS

Operation Mode Status:
This signal is OFF when the current mode is AUTO, or ON when the current
mode is MANU.

3.7.7 (19)

b7 GHMS

Under Home return Operation: This signal remains ON while home return is
in progress.

3.7.7 (6)

b6 PUSHS

Push motion in progress: This signal remains ON while push-motion
operation is in progress.

3.7.7 (25)

b5 PSEL

Pressing and a Miss: This signal turns ON when the actuator missed the
load in push-motion operation.

3.7.7 (23)

b4

SV

Operation preparation end: This signal turns ON when the servo turns ON.

3.7.7 (5)

b3

ALM

Alarm: This signal turns ON when an alarm occurs.

3.7.7 (3)

b2

MOVE

Moving Signal: This signal remains ON while the actuator is moving.

3.7.7 (9)

b1 HEND

Home return completion: This signal turns ON when home return is
completed.

3.7.7 (6)

PLC Input

Status

Signal 2

b0 PEND

Positioning completion signal: This signal turns ON when positioning is
completed.

3.7.7 (10)

Signal Type

Bit

Symbol

Contents

Details