2. ACON-C/CG,

PCON-C/CG


47

CompoNet

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit

Symbol

Contents

Details

Current

Position

32-bit

data

-

32-bit signed integer indicating the current position
The setting unit is 0.01mm.
(Example) Reading:000003FF

H

=1023 (decimal)

=10.23mm
* When the value is read in hexadecimal notation, the negative figure is

expressed as a complement of 2.

2.9 (3)

Command

Current

32-bit

data

-

32-bit integer
The electrical current presently specified by a command is indicated.
The setting unit is mA.
(Example) Reading:000003FF

H

=1023 (decimal)

=1023mA

2.9 (3)

Current

Speed

32-bit

data

-

32-bit signed integer indicating the current position
The current speed is indicated.
Positive value: The actuator is moving in the direction opposite home.
Negative value: The actuator is moving in the direction of home.
The setting unit is 0.01mm/sec.
(Example) Reading:000003FF

H

=1023 (decimal)

=10.23mm/sec
* When the value is read in hexadecimal notation, the negative figure is

expressed as a complement of 2.

2.9 (3)

Alarm Code

16-bit

data

-

16-bit integer
When an alarm is issued, the alarm code is output.
When any alarm is not issued, it is “0”.
Refer to the operation manual for the controller main body for the details of
the alarms.

2.9 (3)

b15

EMGS

Emergency stop: An emergency stop is actuated when this signal turns ON.

2.7.7 (2)

b14

PWR

Controller ready : This signal turns ON when the controller becomes ready.

2.7.7 (1)

b13

ZONE2

Zone 2:“ON” for the current position within the zone set range

2.7.7 (12)

b12

ZONE1

Zone 1:“ON” for the current position within the zone set range

2.7.7 (12)

b11

PZONE

Position zone:
This signal turns ON when the current position is inside the specified position zone.

2.7.7 (12)

ACON

-

Unavailable (ON/OFF is undefined)

-

b10

PCON LOAD

Load output judgment:
When this signal is ON, the specified load has been reached. When the
signal is OFF, the load has not been reached yet.
(Refer to Operation Manual for the controller main body for more
information)

2.7.7 (26)

ACON

-

Unavailable (ON/OFF is undefined)

-

b9

PCON TRQS

Torque level:
When this signal is ON, the specified load has been reached. When the
signal is OFF, the load has not been reached yet.
(Refer to Operation Manual for the controller main body for more
information)

2.7.7 (27)

b8 RMDS

Operation Mode Status:
This signal is OFF when the current mode is AUTO, or ON when the current
mode is MANU.

2.7.7 (19)

b7 GHMS

Under Home return Operation: This signal remains ON while home return is
in progress.

2.7.7 (6)

b6 PUSHS

Push motion in progress: This signal remains ON while push-motion
operation is in progress.

2.7.7 (25)

b5 PSEL

Pressing and a Miss: This signal turns ON when the actuator missed the
load in push-motion operation.

2.7.7 (23)

b4

SV

Operation preparation end: This signal turns ON when the servo turns ON.

2.7.7 (5)

b3

ALM

Alarm: This signal turns ON when an alarm occurs.

2.7.7 (3)

b2

MOVE

Moving Signal: This signal remains ON while the actuator is moving.

2.7.7 (9)

b1 HEND

Home return completion: This signal turns ON when home return is
completed.

2.7.7 (6)

PLC Input

Status Signal

b0 PEND

Positioning completion signal: This signal turns ON when positioning is
completed.

2.7.7 (10)