4. SCON-CA


198

CompoNet

(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”)

Address Bit

Symbol

Function

Details

Acceleration 16-bit

data -

Deceleration 16-bit

data -

16-bit integer.
Specify the acceleration and deceleration at which to move
the actuator.
The unit is 0.01 G, while the specifiable range is 1 to 300.
(Example) To set 0.30 G, specify “30.”
If a move command is issued by specifying “0” or a value
exceeding the maximum acceleration or maximum
deceleration, an alarm will occur.

4.9 (3)

Push-current
limiting value

16-bit data

-

16-bit integer.
Specify the current-limiting value during push-motion
operation.
The specified range is 0 (0%) to 255 (100%).
The actual specifiable range varies with each actuator. (Refer
to the catalog or operation manual for each actuator.)
If a move command is issued by specifying a value exceeding
the maximum push current value, an alarm will occur.

4.9 (3)

Load current

threshold

16-bit data

-

16-bit integer.
If judgment will be made as to whether or not the load current
exceeded the set value, specify the threshold value for current
using this register.
The specifiable range is 0 (0%) to 255 (100%).
If judgment is not performed, enter “0.”

4.9 (3)

b15

b14

-

Cannot be used.

-

b13 NTC1

Vibration
damping control
mode selection 1

b12 NTC0

Vibration
damping control
mode selection 0

Select the vibration damping control
parameter set to be used.

NTC1

NTC0

Function

OFF OFF

Do not use vibration
damping control.

OFF

ON

Select parameter set 1.

ON

OFF

Select parameter set 2.

ON

ON

Select parameter set 3.

4.7.11 (29)

b11

b10

-

Cannot be used.

-

b9

ASO1

Stop mode 1

b8

ASO0

Stop mode 0

Select the stop mode during standby.

ASO1 ASO0

Function

OFF OFF

Invalid (The servo is always
on.)

OFF ON

The servo turns off after the
time is set in parameter No. 36.

ON OFF

The servo turns off after the
time is set in parameter No. 37.

ON ON

The servo turns off after the
time is set in parameter No. 38.

4.7.11 (31)

b7 MOD1

b6 MOD0

Acceleration/deceleration mode:
Trapezoid pattern when both signals are OFF, S-motion when
MOD1 is OFF and MOD0 is ON, or primary delay filter when
MOD1 is ON and MOD0 is OFF.

4.7.11 (30)

b5 GSL1

Servo gain
parameter set
selection 1

PLC output

Control signal 1

b4 GSL0

Servo gain
parameter set
selection 0

Select the servo gain parameter set to be
used.

GSL1 GSL0

Function

OFF

OFF

Select parameter set 0.

OFF

ON

Select parameter set 1.

ON

OFF

Select parameter set 2.

ON

ON

Select parameter set 3.

4.7.11 (33)