IAI America PCON-CFA User Manual

Page 205

Advertising
background image

4. SCON-CA


199

CompoNet


Address Bit

Symbol

Function

Details

b3 INC

Incremental specification:
Absolute position command when the signal is OFF, or
incremental position command when the signal is ON.

4.7.11 (24)

b2 DIR

Push direction specification:
When the signal is OFF, the direction of the position obtained
by subtracting the positioning band from the target position is
used.
When the signal is ON, the direction of the position obtained by
adding the positioning band to the target position is used.

4.7.11 (22)

b1 PUSH

Push specification: Positioning operation when the signal is
OFF, or push-motion operation when the signal is ON.

4.7.11 (21)

Control signal 1

b0

-

Cannot be used.

-

b15 BKRL

Forced brake release: The brake is released when the signal
turns ON.

4.7.11 (18)

b14 RMOD

Operation mode: AUTO mode when the signal is OFF, or
MANU mode when the signal is ON.

4.7.11 (19)

b13

b12

b11

b10

-

Cannot be used.

-

b9 CLBR

Load cell calibration command: Calibration is performed when
this signal turns ON.

4.7.11 (32)

b8 JOG+

+Jog: The actuator moves in the direction opposite home when
the signal is ON.

4.7.11 (13)

b7 JOG-

-Jog: The actuator moves in the direction of home when the
signal is ON.

4.7.11 (13)

b6 JVEL

Jog speed/inching distance switching: Parameter No. 26, “Jog
speed” and parameter No. 48, “Inching distance” are used
when the signal is OFF, or parameter No. 47, “Jog speed 2”
and parameter No. 49, “Inching distance 2” are used when the
signal is ON.

4.7.11 (14)

b5 JISL

Jog/inching switching: Jog operation when the signal is OFF, or
inching operation when the signal is ON.

4.7.11 (15)

b4

SON

Servo ON command: The servo is ON when the signal is ON.

4.7.11 (5)

b3

RES

Reset: A reset is performed when the signal turns ON.

4.7.11 (4)

b2

STP

Pause: A pause command is issued when the signal turns ON.

4.7.11 (11)

b1 HOME

Home return: A home return command is issued when the
signal turns ON.

4.7.11 (6)

PLC output

Control signal 2

b0 DSTR

Positioning start: A move command is issued when the signal
turns ON.

4.7.11 (8)

Advertising
This manual is related to the following products: