4. SCON-CA


190

CompoNet

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit

Symbol

Contents

Details

Current
Position

32-bit

data

-

32-bit signed integer indicating the current position
The setting unit is 0.01mm.
(Example) Reading:000003FF

H

=1023 (decimal)

=10.23mm
When the value is read in hexadecimal notation, the negative figure is
expressed as a complement of 2.

4.9 (2)

Command
Current

32-bit

data

-

32-bit integer
The electrical current presently specified by a command is indicated.
The setting unit is mA.
(Example) Reading:000003FF

H

=1023 (decimal)

=1023mA

4.9 (2)

Current
Speed

32-bit

data

-

32-bit signed integer indicating the current position
The current speed is indicated.
Positive value: The actuator is moving in the direction opposite home.
Negative value: The actuator is moving in the direction of home.
The setting unit is 0.01mm/sec.
(Example) Reading:000003FF

H

=1023 (decimal)

=10.23mm/sec

* When the value is read in hexadecimal notation, the negative figure

is expressed as a complement of 2.

4.9 (2)

Alarm Code

16-bit

data

-

16-bit integer
When an alarm is issued, the alarm code is output.
When any alarm is not issued, it is “0

H

”.

Refer to the Operation Manual for the controller main body for the
details of the alarms.

4.9 (2)

b15 EMGS

Emergency stop: An emergency stop is actuated when this signal turns
ON.

4.7.11 (2)

b14 PWR

Controller ready : This signal turns ON when the controller becomes
ready.

4.7.11 (1)

b13

ZONE2 Zone 2:“ON” for the current position within the zone set range

4.7.11 (12)

b12

ZONE1 Zone 1:“ON” for the current position within the zone set range

4.7.11 (12)

b11

b10

b9

-

Unavailable -

b8 RMDS

Operation Mode Status:
This signal is OFF when the current mode is AUTO, or ON when the
current mode is MANU.

4.7.11 (19)

b7

BALM

Absolute battery voltage low warning: This signal turns ON when the
voltage drops.

4.7.11 (28)

b6

-

Cannot be used.

-

b5

PSEL

Pressing and a Miss: This signal turns ON when the actuator missed
the load in push-motion operation.

4.7.11 (23)

b4

SV

Operation preparation end: This signal turns ON when the servo turns
ON.

4.7.11 (5)

b3

ALM

Alarm: This signal turns ON when an alarm occurs.

4.7.11 (3)

b2

MOVE

Moving Signal: This signal remains ON while the actuator is moving.

4.7.11 (9)

b1

HEND

Home return completion: This signal turns ON when home return is
completed.

4.7.11 (6)

PLC Input

Status
Signal

b0

PEND

Positioning completion signal: This signal turns ON when positioning
is completed.

4.7.11 (10)