background image

4. SCON-CA


216

CompoNet

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit

Symbol

Contents

Details

Pressing

Current

Limit

Value

16-bit

data

-

16-bit integer
Specify the current-limiting value to be used during push-motion
operation.
The allowable specification range is 0 (0%) to 255 (100%).
The actual settable range varies depending on each actuator.(Refer
to the catalog or Operation Manual for the actuator.) If a move
command is issued by specifying a value exceeding the maximum
push-motion current, an alarm will occur.

4.9 (2)

b15

BKRL Forced brake release: When it is turned ON, the brake is released.

4.7.11 (18)

b14 RMOD

Operating mode selector: The AUTO mode is selected when this
signal is OFF, and the MANU mode is selected when the signal is
ON.

4.7.11 (19)

b13 DIR

Push direction specification:
“OFF” for the direction reducing the positioning band from the target
position,
“ON” for the direction adding the positioning band to the target
position

4.7.11 (22)

b12 PUSH

Push-motion specification: Positioning operation is performed when this
signal is OFF, and push-motion operation is performed when the signal is
ON.

4.7.11 (21)

b11

b10

-

Unavailable

-

b9

CLBR

Load cell calibration command: Calibration is performed when this signal
turns ON.

4.7.11 (32)

b8

JOG+ + Jog: “ON” for Movement in the Opposite Direction of Home

4.7.11 (13)

b7

JOG-

-Jog: “ON” for Movement to the Home Direction

4.7.11 (13)

b6 JVEL

Jog-speed/inch-distance switching:
The values set in parameter No. 26, “Jog speed” and parameter No.
48, “Inch distance” are used when this signal is OFF, and the values
set in parameter No. 47, “Jog speed 2” and parameter No. 49, “Inch
distance 2” are used when the signal is ON.

4.7.11 (14)

b5 JISL

Jog/inch switching:
Jog operation is performed when this signal is OFF, and inch
operation is performed when the signal is ON.

4.7.11 (15)

b4

SON

Servo ON Command: The servo turns ON when this signal turns ON.

4.7.11 (5)

b3

RES

Reset: A reset is performed when this signal turns ON.

4.7.11 (4)

b2

STP

Pause: A pause command is issued when this signal turns ON.

4.7.11 (11)

b1 HOME

Home return: A home-return command is issued when this signal
turns ON.

4.7.11 (6)

PLC Output

Control

Signal

b0 DSTR

Positioning Command: A move command is issued when this signal
turns ON.

4.7.11 (8)